Water tank design by IS 3370 2009

Post new topic Reply to topic Thank Post    www.sefindia.org Forum Index -> SEFI General Discussion
View previous topic :: View next topic
Author Message
bharat bhushan jindal
SEFI Member
SEFI Member

Joined: 24 Sep 2011
Posts: 5
Location: CHANDIGARH


Post Posted: Sat Sep 24, 2011 1:39 am   Post subject: Water tank design by IS 3370 2009 Reply with quote

Dear Safians .

Can any body please provide me the water tank design with LSM as per Is 3370 / 2009.

Pls also explain the surface zones specified in Is 3370 Part II/ 2009 for reinforcement.

Back to top

View user's profile Send private message

rajancivildesign@gmail.co
...
...

Joined: 26 Jan 2011
Posts: 563


Post Posted: Sat Sep 24, 2011 9:58 am   Post subject: WATER TANK DESIGN BY LSM Reply with quote

Dear SAFIAN,
For limit state design of WATER TANK refer Reinforced concrete limit state design by Ashok Jain. Since the code has revised in 2009, no Indian books are available for design of water tank by LSM. However a book similar to IS 3370 is available in the form of soft copy. "Design of Liquid Retaining Concrete Structures" by Robert D.Anchor using British code. You can send  a request to my email Id. rajancivildesign@gmail.com.
Regarding zones in IS 3370 part 2, there are 3 zones for grounded  slabs. zone 1, reinforcement shall be provided for top surface for a depth of D/2 for slab iwithin 300mm thick. For zone 2, when D is between 300 mm to 500mm, the reinforcement minimum shall be provided for top for D/2 portion. When D>500 mm , in case of
zone 3 the reinforcement shall be provided for bottom surface zone only 100 mm thick. Kindly refer Ashok Jain Rcc book.
V.M.RAJAN.
Back to top

View user's profile Send private message

rajancivildesign@gmail.co
...
...

Joined: 26 Jan 2011
Posts: 563


Post Posted: Sat Sep 24, 2011 1:19 pm   Post subject: CRACK WIDTH IN CASE OF WATER TANK DESIGN Reply with quote

Dear SAFIAN,
In case of Side wall of under ground water tank, the crack width is limit to 0.1mm for aggressive environment and 0.2mm for normal environment. Whether this crack width check is mainly for outer bar of main rods. Is it necessary to check the crack width for distributors also which is placed inside the main rod. Kindly clarify with relevant class in the code if any.
V.M.RAJAN.
Back to top

View user's profile Send private message

venkatesh
General Sponsor
General Sponsor

Joined: 29 Dec 2008
Posts: 218


Post Posted: Mon Sep 26, 2011 4:49 am   Post subject: Reply with quote

Dear Er Bharath

Lot of discussions have been made in past postings in this forum. you can browse following links
http://www.sefindia.org/forum/viewtopic.php?p=27026

http://www.sefindia.org/forum/viewtopic.php?t=6016

thanks & regards
Venkateshwara Rao

Back to top

View user's profile Send private message

bharat bhushan jindal
SEFI Member
SEFI Member

Joined: 24 Sep 2011
Posts: 5
Location: CHANDIGARH


Post Posted: Wed Sep 28, 2011 6:23 am   Post subject: Re: WATER TANK DESIGN BY LSM Reply with quote

rajancivildesign wrote:
Dear SAFIAN,
For limit state design of WATER TANK refer Reinforced concrete limit state design by Ashok Jain. Since the code has revised in 2009, no Indian books are available for design of water tank by LSM. However a book similar to IS 3370 is available in the form of soft copy. "Design of Liquid Retaining Concrete Structures" by Robert D.Anchor using British code. You can send  a request to my email Id. rajancivildesign@gmail.com.
Regarding zones in IS 3370 part 2, there are 3 zones for grounded  slabs. zone 1, reinforcement shall be provided for top surface for a depth of D/2 for slab iwithin 300mm thick. For zone 2, when D is between 300 mm to 500mm, the reinforcement minimum shall be provided for top for D/2 portion. When D>500 mm , in case of
zone 3 the reinforcement shall be provided for bottom surface zone only 100 mm thick. Kindly refer Ashok Jain Rcc book.
V.M.RAJAN.

Thanks Rajan Sir for responding to my query..... i'm still in doubt whether during calculation for minimum reinforcement we have to take  D/2 depth portion of slab or it is for the purpose of reinforcemetn details only.

regards

Bharat Bhushan Jindal

Back to top

View user's profile Send private message

Display posts from previous:  
Post new topic Reply to topic Thank Post    www.sefindia.org Forum Index -> SEFI General Discussion All times are GMT
Page 1 of 1

 

Jump to: 

You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum

© 2003, 2008 SEFINDIA, Indian Domain Registration
Publishing or acceptance of an advertisement is neither a guarantee nor endorsement of the advertiser's product or service. advertisement policy

Design of Water Tank Using Is 3370-2009

Source: https://www.sefindia.org/forum/viewtopic.php?p=40804

0 Response to "Design of Water Tank Using Is 3370-2009"

إرسال تعليق

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel